Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 1Model(s): QFP44Owner’s ManualInstallation and OperationInstallation and service of this appliance should
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0810Clear Space3 ft (0.91 m)in front ofapplianceC. Clear SpaceWARNING! DO NOT place combustible objects in f
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 11Ignitor Battery Box By pulling the drawer forward, the ignitor battery box can be accessed to replace t
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0812Remote ReceiverThe remote receiver has a 3-position slide switch: OFF/REMOTE/ON (see Figure 2.5).NOTE:
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 131. LOW - Battery power low. Replace batteries within two weeks.2. TIMER - Indicates time remaining be
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0814Setting °F/°C ScaleThe factory setting for temperature is degrees Fahrenheit °F). To change this setting
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 15Adjusting the Flame Height -Operates in ON or THERMO modeThis remote control system allows the user to
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0816H. Before Lighting FireplaceBefore operating this replace for the rst time, have a quali ed service
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 171. Turn unit off with remote.2. Turn off all electric power to the appliance if service is to be perf
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0818Initial Break-in Procedure• The fireplace should be run three to four hours continuously on high.• Tur
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 19Glass CleaningFrequency: SeasonallyBy: HomeownerTools Needed: Protective gloves, glass cleaner, drop
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/082Listing Label Information/LocationModel Name: ___________________________________________ Date purchased/
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0820VentingFrequency: SeasonallyBy: HomeownerTools needed: Protective gloves and safety glasses.• Inspect
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 21Figure 3.1 Standing Pilot Flame Patterns
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0822Noncombustible roof flashing maintains minimum clearance around pipe(SECTION 10)Ceiling Firestopon floor
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 23B. Design and Installation ConsiderationsQuadra-Fire direct vent gas appliances are designed to operate
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08245 5 Framing and Clearances A. Select Appliance LocationWhen selecting a location for the appliance it
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 25Combustible flooring may be installed next to the front of the appliance. ALL SURFACES MUST BE FLUSHWIT
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0826MantelNon-combustibleFaceAA = 53 in. (1346 mm) min.Non-combustible Mantel12 in. (308 mm) maximum depth A
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 27Direct Vent Gas, Wood or FuelOil Termination20 in.(508 mm)(minimum) toPerpendicularWall(DV only)Wood, G
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0828Dimension Descriptions A Clearance above the ground, a veranda, porch, deck or balcony - 12 in. (30 cm)
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 29HorizontalVertical 8-1/2 in.8-1/2 in. 12 in.On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in.
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 3 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided will result in deat
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0830H1V1To replace the rst starter elbow with two 45° elbows, refer to Figure 7.4. All other 90° elbows c
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 314 ft min. (1.22 m) 17 ft max.(5.18 m)3 ft min. (.91 m) 1. Top Vent - Horizontal Termination - (contin
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08322. Top Vent - Vertical TerminationNo ElbowFigure 7.7Figure 7.8Two ElbowsNote: If installing a vertical
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 33Figure 7.92. Top Vent - Vertical Termination - (continued)Three Elbows12 ft (3.66 m) min.60 ft (18.29
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0834No combustible framing to be located within shaded area. 1-1/2 in. (13 mm)minimum toperpendicularwall.WA
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 35C. Install the Ceiling FirestopA ceiling restop MUST be used between oors and at-tics.• Frame an o
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0836Bend all tabs inward 90° to maintain clearance and prevent insulation from falling insideInsert 3 screws
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 37A. Secure and Level the ApplianceWARNING! Risk of Fire! Prevent contact with:• Sagging or loose insula
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0838Lances10 10 Install Vent Pipe A. Assemble Vent SectionsAttach Pipe to the Firebox AssemblyNote: The e
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 39B. Assemble Slip SectionsWARNING! Risk of Fire or Asphyxiation! Overlap pipe sections at least 1 1/2 in
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/084Î = Contains updated information.14 Appliance Setup A. Remove Glass Assembly 54B. Clean the Appliance
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0840Figure 10.7 Securing Vertical Pipe SectionsFigure 10.8 Securing Horizontal Pipe SectionsD. Disassemble
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 41E. Install Metal Roof FlashingNote: Skip to Section 10.I. if using the RF4-8.• See minimum vent height
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0842F. Assemble and Install Storm CollarCAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 43G. Install RF4-8The RF4-8 may be used in place of the roof ashing and storm collar. Pipe must be supp
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0844Important Notice: Heat shields may not be eld constructed.I. Heat Shield Requirements for Horizonta
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 45INTERIORHeat Shield orExtendedHeat ShieldWall ShieldFirestopHeat Shield1-1/2 in. (38 mm) min.overlapSHE
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0846A. Fuel Conversion• Make sure the appliance is compatible with available gas types.• Conversions must
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 47Control KnobScrew (pressure adjustment)Pin (blue-NG, red-LP)SolenoidLock NutFigure 11.7 Valve Componen
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0848C. Gas Connection • Refer to Reference Section 16.A. for location of gas line access in appliance.• Ga
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 49B. Standing Pilot Ignition System Wiring• The standing pilot ignition system wiring does not require a
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 5B. Limited Lifetime WarrantyWarranty Period HHT Manufactured Appliances and VentingComponents CoveredPar
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0850D. Electrical Service and RepairWARNING! Risk of Shock! Label all wires prior to disconnection when serv
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 51MantelNon-combustibleFaceAA = 53 in. (1346 mm) min.Non-combustible Mantel12 in. (308 mm) maximum depth
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08520 in. 0 in. 0 in. Finish wall material may be combustible - Top and SidesHigh Temperature Sealant (300°
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 5314 14 Appliance Setup C. Install the Refractory• Remove the refractory retainer from each side of th
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0854• Install the upper back refractory.Figure 14.4 Install Upper Back Refractory• Install the right side
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 55Figure 14.7 Adjust the Vertical Baf eFigure 14.8 Positioning Rear LogF. Install Logs, Ember Bed &am
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0856• Position the right front log over the grate bars, aligning the cut outs on the bottom of the log with
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 57WARNING! Risk of Explosion! Follow rockwool placement instructions. DO NOT place rockwool directly ove
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0858A. Standing Pilot Ignition System15 15 Troubleshooting With proper installation, operation, and mainten
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 59Troubleshooting (continued)Symptom Possible Cause Corrective Action3. (Continued) C. Failed valve. Turn
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/086gasketing, glass discoloration, rebrick, pellet logs, kaowool or other ceramic insulating materials. R
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/086016 16 Reference Materials 49 in.1245 mm40 in.1016 mm35-1/2 in.902 mmA. Appliance Dimension DiagramDime
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 61B. Vent Components DiagramsFigure 16.2 DVP Vent Components EffectiveHeight/LengthDVP Pipe(see ch
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0862B. Vent Components Diagrams (continued)Figure 16.3 DVP Vent Components13-1/4 in.(367 mm)24-5/8 in.(625
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 63B. Vent Components Diagrams (continued)Figure 16.4 DVP Vent Components7-1/4 in.(184 mm)5-1/4 in.(133
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0864B. Vent Components Diagrams (continued)Figure 16.5 DVP Vent Components DVP-TRAP1DVP-TRAP2DVP-HPC1DV
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 65C. Service Parts13141718201619152831322930262422212723256317425Log Set AssemblyRefractory Assembly89101
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08662423221226192016345101198613725141715182121Service PartsQFP44 Service Parts Diagram44 in. Gas Appliance
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 67D. Optional ComponentsDoor (iron full view) DF-QFP44-IFVDoor (iron operable) DF-QFP44-IOPDoor (Craftsma
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/0868E. Contact InformationPlease contact your Quadra-Fire dealer with any questions or concerns. For the loc
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 7C. BTU Speci cationsMODELS: QFP44LABORATORY: Underwriters Laboratories, Inc. (UL)TYPE: Direct Vent Ga
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/088H. Requirements for the Commonwealth of MassachusettsFor all side wall horizontally vented gas fueled equ
Quadra-Fire • QFP44 • 4051-300 Rev M • 09/08 9Decorative Doors(not shown)Section 2.E.Fixed Glass AssemblySection 2.F.MantelHearth(not required)Dashboa