Quadra-Fire QV32B-A Especificações

Consulte online ou descarregue Especificações para Lareiras Quadra-Fire QV32B-A. Quadra-Fire QV32B-A Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
1Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06
Models:
QV32B
QV36B
Installers Guide
Underwriters
Laboratories Listed
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Quadra-Fire dealer
with any questions or concerns. For the
number of your nearest Quadra-Fire
dealer, please visit www.quadrafire.com.
Printed in U.S.A. Copyright 2006
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
Quadra-Fire, a brand of Hearth & Home Technologies
1445 North Highway, Colville, WA 99114
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802,
6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250,
780403, 1418504 or other U.S. and foreign patents pending.
In the Commonwealth of Massachusetts:
installation must be performed by a licensed
plumber or gas fitter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Vista de página 0
1 2 3 4 5 6 ... 38 39

Resumo do Conteúdo

Página 1 - Installers Guide

1Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Models:QV32BQV36BInstallers GuideUnderwritersLaboratories Listed- Do not store or use gaso

Página 2

15Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 5. Framing DimensionsStep 2. Framing the FireplaceFireplace framing can be built b

Página 3 - TABLE OF CONTENTS

16 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06NOTE: PIPES OVERLAP 1-1/4 INCHES(34.93mm) AT EACH JOINT.Figure 6. DVP-Series Direct Ve

Página 4 - Approvals and Codes

17Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06NOTE: PIPES OVERLAP 1-3/8 INCHES (34.93mm) AT EACH JOINT.Figure 7. SL D-Series Direct Ve

Página 5 - Massachusetts

18 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 3. Installing the Vent SystemA. Vent System ApprovalsThese models have vent starti

Página 6 - Getting Started

19Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06STRAIGHT UPVERTICAL VENTINGV (FT.)45' MAX.Figure 10.Straight up Vertical VentingUse S

Página 7

20 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 13. Venting with One 90° ElbowUse SL D-Seriescomponents only.MODEL QV32BV (MIN.) H

Página 8

21Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06V H H + H11' MIN. (305 mm) 2' MAX. (610 mm) 4' MAX. (1.22m)2' MIN.

Página 9 - Installing the Fireplace

22 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 15. Venting with Two 90° ElbowsMODEL QV32BV (MIN.) H + H1 (MAX.)90o Elbow on Top

Página 10

23Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 16. Venting with Two 90° ElbowsMODEL QV32BV (MIN.) H (MAX.)90o Elbow on Top 2.5 FT

Página 11 - (34.93mm) AT EACH JOINT

24 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 17. Venting with Three 90° elbows1' MIN. (305 mm) 2' MAX. (610mm) 4&

Página 12

2 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06These units MUST use one of the vent systemsdescribed in the Installing the Fireplace sect

Página 13 - Identifying Vent Components

25Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 18. Venting with three 90° elbowsUse SL D-Series components only. MODEL QV

Página 14 - Flex Vent

26 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Use SL D-Series components only.Figure 19. Venting with three 90° elbowsMODEL QV32BV (MIN

Página 15

27Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 20. Venting with Four 90° elbowsVENTING WITH FOUR (4) 90° ELBOWS NATURAL AND PRO

Página 16 - Use DVP-Series

28 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06B. Installing Vent ComponentsAfter determining which set of starting collars will be use

Página 17 - Use SL D-Series

29Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Runs - The vent system must be supportedevery eight (8) feet (2.4m) above the

Página 18

30 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Runs - One ceiling firestop is REQUIRED atthe hole in each ceiling through w

Página 19 - components only

31Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06C. Vent TerminationSL-Series Venting Only:For Horizontal Terminations - To attach and sec

Página 20

32 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06V= VENT TERMINALX= AIR SUPPLY INLET= AREA WHERE TERMINAL IS NOT PERMITTED Figure 30.

Página 21

33Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For Vertical Terminations - To locate the vent and installthe vent sections:• Locate and m

Página 22 - 90° ELBOWS

34 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 4. Positioning, Leveling, and Securing the Fireplace• Place the firep

Página 23 - DVP Series Venting Only:

3Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06TABLE OF CONTENTSSafety and Warning Information ...

Página 24

35Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 34. Gas Supply Line• Insert insulation from the outside of the fireplace andpack

Página 25

36 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 8. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelect

Página 26 - For All Venting:

37Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 9. FinishingFigure 38 shows the minimum vertical and correspondingmaximum horizontal

Página 27 - (See Note 5)

38 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Placing the Ember MaterialEmber material is shipped with this gas fireplace. The baglabel

Página 28 - (DVP PIPE)

39Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 11. Lighting the ApplianceSTANDING PILOT IGNITIONA. This appliance (standing pilot

Página 29 - STANDING PILOT

40 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Step 12. Before Lighting the FireplaceBefore lighting the fireplace, be sure to do the

Página 30 - Step 6. The Gas Supply Line

41Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/064Maintaining and Servicing Your FireplaceFireplace MaintenanceAlthough the frequency of yo

Página 31 - Step 8. Wiring the Fireplace

42 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06TroubleshootingWith proper installation, operation, and maintenance your gas fireplacewil

Página 32 - Step 9. Finishing

43Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Symptom Possible Cause Corrective Action3. (Continued) f. High limit switch is defective o

Página 33 - ASSEMBLY

44 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Lifetime WarrantyLIMITED LIFETIME WARRANTYThe Hearth & Home Technologies limited Life

Página 34

9Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/061Approvals and CodesNOTE: THESE MODELS ARE UL LISTED TO UL307B,THE STANDARD FOR GAS-BURNING

Página 35 - After the Installation

10 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06For all side wall horizontally vented gas fueled equipmentinstalled in every dwelling, bu

Página 36 - Fireplace Maintenance

11Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/062Getting StartedIntroducing the Village CollectionGas FireplacesThe Village Collection dir

Página 37 - Troubleshooting

12 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06RATING PLATE/LABELSGASACCESSGASCONTROLSELECTRICALACCESSTOP STANDOFFSGASLINEACCESS5 1/16(1

Página 38 - Troubleshooting (continued)

13Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/06Figure 2. Diagram of the QV32BÎRATING PLATE/LABELSGASACCESSGASCONTROLSELECTRICALACCESSTOP

Página 39 - Lifetime Warranty

14 Quadra-fire • QV32B, QV36B • 2013-900 Rev. F • 9/063Installing the FireplaceStep 1. Locating the FireplaceSpace and clearance requirements

Comentários a estes Manuais